Compressive strength test of brick, cement mortar, concrete and other building materials. It can also be used for mechanical properties test of other materials. The computer controls the lifting of the machine screw without manual operation. Semi-automatic compression testing machine adopts hydraulic loading, electronic force measurement, with load digital display, maximum load maintenance and power-off data protection functions. Automatic test data processing and printing out test reports.

Semi-Automatic Compression Testing Machine

 

Semi-automatic Compression Testing Machine
  • CE Certification

  • High Precision Sensor

  • Easy Operation

  • Digital Display

  • High Reliability, Zero Leakage

  • Automatic Data Processing

Ask For Inquiry

Product Specification

1Product ModelTSY-2000B 
2Max Test Force2000kn
3Measure Range5-100%
4Load Indication Accurancy±1/±0.5%
5Max Pressing Space320mm
6Bearing Plate Diameter300*260mm
7Oil Pump Motor Power0.75kw
8Control Cabinet470*600*1500mm
9Net Weight900kg
1Product ModelTSY-3000B 
2Max Test Force3000kn
3Measure Range5-100%
4Load Indication Accurancy±1/±0.5%
5Max Pressing Space330mm
6Bearing Plate Diameter320*320mm
7Oil Pump Motor Power0.75kw
8Control Cabinet500*700*1700mm
9Net Weight1200kg

Product Details

Automatic Compression Testing Machine DETAILS

English vision, turn on/off machine, load data auto save/print, oil motor control, leading screw adjusting, etc

Return valve and delivery valve

Oil lever, quality oil cover

output signal 4-20MA, screw connect.

Application

  • Concrete

  • Cement paste

  • Brick

  • Other Conctructions

Who like to use

  • Construction engineering inspection unit

  • Quality supervision department

  • Colleges and Universities

  • Large-scale industrial and mining enterprises

  • Government sector

  • Research institute

Introduction of Tester

How To Install Semi-Automatic Compression Testing Machine?

  • Semi-auto compression testing machine after unpacking, the body has a lifting screw hole on nylon cover, opened a nylon plug, M20 random belt lifting screw is screwed into the threaded hole, with lifting machinery hanging to the preset place. When handling, pay attention to the protruding part of the machine
  • In order to facilitate operation, the machine should be placed on the prefabricated 720mmx600mm higher than the ground 300mm cement. After compression testing machine has been transferred to the horizontal installation, clean the cotton yarn soaked with kerosene, wipe the rust inhibitor on the surface of the machine, and then wipe the surface with a thin layer of machine oil.

What is Semi-auto Compression Testing Machine?

Semi-automatic compression testing machine’ screw rod lifting controlled by the computer software without manual operation. 

  • Compression testing machine: the measuring accuracy is + 1%, and the failure load of the specimen should be greater than 20% of the full range of the press, and less than 80% of the total range of the press. It shall be equipped with a loading speed display device or a loading speed control device, and shall be uniformly and continuously loaded.
  • The concrete strength grade of greater than or equal to C60, the specimen should be fortified around cracking device. The plane tolerance of the upper and lower platen of the test machine is 0.04mm, the surface hardness is not less than 55HRC, and the thickness of hardened layer is about 5mm. If not conform to the requirements, the thickness should be no less than 25mm, flatness and hardness of the same test machine and steel plate.

How To Test Concrete?

  1. After the specimen is taken out from the maintenance site, the test shall be carried out in time, and the surface of the test piece and the upper and lower pressure bearing surfaces shall be wiped clean.
  2. Place the test piece on the lower platen or shim plate of the test machine. The bearing surface of the specimen shall be perpendicular to the top surface of the forming. The specimen should be the center and testing machine under the plate center alignment, start the test machine when the plate and specimen or steel plate close, adjust the tee, make contact balance.
  3. In the course of the experiment should be continuous and uniform loading, concrete strength grade “C30, the loading speed per second 0.3~0.5MPa; concrete grade of strength over C30 and C60”, from 0.5~0.8MPa per second; the concrete strength grade of greater than or equal to C60, from 0.8~1.0MPa per second.
  4. When the specimen is close to the beginning of a sharp deformation of the damage, the test machine shall stop adjusting the throttle until it is destroyed, and then record the damage load.
  5. Cube compressive strength test results are calculated and determined according to the following methods:
  • concrete cube compressive strength should be calculated by pressing:
  • Fcc=F/A  Type:
  • FCC: compressive strength of concrete cube specimen (MPa);
  • F: specimen failure load (N);
  • A: the specimen bearing area (m m).
  • Concrete cube compressive strength calculation should be accurate to 0.1MPa.
  • The determination of the strength value shall comply with the following provisions:The arithmetic mean of the three test values is used as the strength value of the group test (0.1MPa).
  • The maximum or minimum value in the three measurements, if there is a difference of between 15% and the middle value, exceeds the maximum and minimum values, and takes the middle value as the compressive strength value of the set of specimens.
  • The maximum or minimum values in the three measurements, such as the difference between the two and the intermediate values, exceed 15% of the mean value, the test data is invalid.
  • (Concrete strength grade) C60, the strength value measured by nonstandard specimen should be multiplied by the dimension conversion factor, the value is 200mm * 200mm * 200mm, the specimen is 1.05; the 100mm * 100mm * 100mm specimen is 0.95.
  • When the concrete strength is more than C60, should adopt the standard specimen; the use of non standard specimen, determine the test size conversion coefficient should be.